The EniCom 2G communicator is recommended where backup signal transmission and EN54-21 certification are required. 

The GSM module is an ideal solution for signal transmission of fire alarm centres via the GSM/GPRS/LTE/IP channel.

  •     4 doubling inputs (8 inputs): NO/NC /EOL/ 2 EOL/ zone doubling
  •     2 OC outputs NO/NC/Follower (input, output, event)
  •     Expantion option with the EC-84 (8 inputs, 4 outputs/expansion panel)
  •     max. 8 pcs EC-84 expansion panel can be connected in one EniCoom system
  •     Forwarding to 4 remote monitoring servers with multiple route options
  •     256 event log with time stamp
  •     2G connection, Dual SIM nano (2 SIM cards)
  •     Ethernet connection
  •     SIA DC-09, Enigma protocol
  •     EN 54-21 certification

EniCom 2 G

EniCom 2G communicators are recommended for security and fire protection applications, where the signal transmission to the remote monitoring centre must be solved by providing a redundant transmission path. The main transmission direction is the Ethernet network; the mobile network (GPRS) can be used as a backup. In all cases, communication takes place using a standard IP-based protocol.

EniCom 2G communicators can send messages to the monitoring station receiver(s) via Ethernet or mobile internet. Four independent communication paths can be defined, each with 3 communication channels (Ethernet and Modem: 2pcs GSM networks, thanks to the 2 SIM cars), to which four arbitrary servers can be assigned on different media (Ethernet or GPRS).

The communicator can manage two SIM cards, so if the primary service provider is unavailable, it can also connect to the network of the secondary service provider.

The loop type of the inputs can be programmed as NC or NO, without or with 1 or 2 EOL resistors, or can be doubled using 3 EOL resistors. The standard value for EOL resistors is 1kΩ. In case of zone doubling, the 3rd EOL resistor should be 2kΩ. EC-84 expansion module selectable input types NO/NC EOL.

  •     Instant two-way transfer (Contact ID)
  •     Plastic housing, SMA antenna connector
  •     Automatic configuration of network settings (DHCP)
  •     Send to four remote monitoring stations via Ethernet
  •     Send to four remote monitoring stations on GPRS
  •     Backup / Parallel / GPRS transmission modes only
  •     Remote programmability
  •     SMS forwarding to 1 specified phone number
  •     256 event buffer memory
  •     Encryptable communication
  •     Configuration via USB
  •     The main functions can be programmed with SMS messages
  •     Four own inputs that can be doubled with adjustable event codes can be extended with EC-IO84 panel with 8 inputs and 4 outputs (optional) max. 8 can be connected (64/32 inputs/outputs in total)
  •     Upgradeable firmware